First, bath, shower room maintenance and precautions
1, bathtub products
A maintenance
(1) Do not hit or scratch the surface of the product with hard objects to avoid scratching the product.
(2) Bathtub installation location should try to avoid heating or heating pipes. If it can't be avoided, it should be at least 10cm away from the heating or heating pipe, separated by a baffle, so as not to scald the bathtub tubing. Or cause the bathtub to deform.
(3) The product should be installed so that all mats are in good contact with the ground.
(4) The product has been equipped with a power lead and a touch-leakage protector at the time of shipment, and this device must not be removed or replaced at will.
(5) The power plug must be connected to a well-grounded power supply line.
(6) When using, firstly put cold water and then put hot water to avoid burning accidents and product damage.
(7) Unplug the power supply when it is not used for a long time.
(8) When the product is used for the first time or when it is not used for the first time for a long time, it should first be checked whether the leakage protector is working normally after the power is turned on (Method: Press the reset button, the power indicator is on, press the test button, the power is off, indicating The lamp is off, otherwise the protector will malfunction and need to be replaced by a professional.) After adding water, first allow the pump to idle for a few minutes to ensure that there is no abnormality before use.
(9) In the event of a mechanical or electrical failure during use, contact your local supplier for repairs.
B maintenance
The massage jars produced by our factory are normally used without maintenance, as long as they are clean, and the following points should be noted when cleaning:
(1) Use neutral detergent, scrub with a soft cloth or towel, do not use strong alkali, acetone and other solutions.
(2) If there is a slight scratch during use, use 1500# to 2000# water-abrasive paper water mill to dip a few toothpastes and wipe it repeatedly at the scratched part to be bright as new.
(3) After each use, use a dry towel to wipe the water droplets and traces on the product to keep the product look beautiful.
C notes
(1) This product is not allowed to be used outdoors or in places where toilet facilities are not required.
(2) Jacuzzi Pay attention to the water level as required by the instruction manual, otherwise the pump will not start.
(3) The shower room and the bathtub should be stored in the normal temperature environment and cannot be piled up. It is forbidden to mix with organic solvents such as formic acid and formaldehyde, and there should be no corrosive gas around.
2. Shower room (represented by steam room)
A maintenance
(1) When the product is transported, it should avoid bumping, and it must be handled in strict accordance with the marking on the product packaging box to avoid damage to the product.
(2) Do not bump or scratch the surface of the product with hard objects to avoid scratching the product.
(3) The steam room should be installed as far as possible to avoid heating or heating pipes. If it is not possible to open the room, it should be at least 10cm away from the heating or heating pipes so as not to scald the bathtub pipes or deform the bathtub.
(4) When installing the product, make sure that all the mats are in good contact with the ground, the bolts are firmly connected, and the bottom basin, top cover and back plate, and water blocking screen are closed tightly.
(5) The product has been equipped with a power lead and a touch-leakage protector at the time of shipment, and this device must not be removed or replaced at will.
(6) The ground wire of the appliance must be connected to the ground wire of a well-grounded power supply line.
(7) Unplug the power supply when it is not used for a long time. All patients with hypertension, diabetes, and heart disease have their steam function disabled.
(8) When the product is used for the first time or is used for the first time after it is not used for a long time, it shall be checked first whether the leakage protector is working normally after power on (Method: Press the reset button, the power indicator is on, press the test button, and the power is off. The indicator light is off, otherwise the protector malfunctions and needs to be replaced by a professional.) After the steam room is equipped with a surf function, the pump is allowed to idle for a few minutes to ensure that there is no abnormality before it can be used.
(9) In the event of a mechanical or electrical failure during use, contact your local supplier for repairs. Do not repair it yourself.
B. Maintenance
The steam room produced by our factory is normally used without maintenance, as long as it is clean, and the following points should be noted when cleaning:
(1) Use neutral detergent, scrub with a soft cloth or towel, and do not use strong alkali, strong acid cleaners and gloss agents, and alcohol and acetone solutions. Sterilize disinfectants such as formic acid or formaldehyde when disinfecting.
(2) If there is a slight scratch during use, use a cotton towel dipped in a little toothpaste to wipe it repeatedly at the scratched area to be bright as new.
(3) After each use, use a dry towel to wipe the water droplets and traces on the product to keep the product look beautiful.
C. Precautions
(1) This product is not allowed to be used outdoors or in places where toilet facilities are not required.
(2) Before starting the steam generator, make sure that the mixing valve is switched to the steam generator inlet function, otherwise the steam generator will dry and cause damage.
(3) The HD140-HD170 surfing bathtub often has problems with the water level switch bad cartridge phenomenon in the after-sales service.
A water level switch can only be updated; the solution for the floater post is: remove the float, shake it by hand, hear a sound inside, prove that the float is active, add a certain height after installation, and plug in the power supply. The computer control panel light is on, if the light is normal;
b The float inlet pipe has certain deposits due to the regular bath, which will cause the water pipe to be lightly plugged or blocked, so that the sub switch cannot be normally connected. The whole machine cannot work. The solution is to remove the water pipe and use a pump to make a few hits. Good;
c Some users do not need to store them for a long period of time. The motor shaft rusts. When the motor is started, a humming sound is generated. However, the motor does not rotate. If this problem is found, it cannot be forced to start. If the motor is forced to start, the motor will be destroyed. The method is to use a common pliers spindle motor spindle gently turn, and then start the motor is good;
d The hydraulic size and the bottom light are not bright. First, check whether the contact is good on the wiring. If the power box is normal, check whether the BLX-Z type fuse is good. If it is bad, it will be updated. Everything will be normal.
Second, all types of installation precautions
Ordinary cylinder
1) Firstly install the sewage and seal the glass glue. Test the water to confirm that there is no water leakage and then proceed with the next step.
2) When installing, pay attention to the full support of the bottom of the bathtub (usually fill dry sand). The top edge of the bathtub should be filled with the level of contact with the table top to ensure that the entire bathtub is evenly loaded. And can ensure smooth bathtub drainage.
3) Note that there are openings (200 x 300 high) for repairs at the wall.
Skirt cylinder
1) Before installation, first check whether the mat is leveled, test whether there is a leak, and whether the drainage is smooth. After confirmation, insert the bathtub water into the sewer pipe and move the bathtub to the placing position.
2) Hit the glass seal against the wall. Prevent splashing water from flowing to the ground.
3. Massage cylinder
1) After unpacking, check the packing list for completeness of the accessories and confirm the installation before proceeding.
2) Place the bathtub in the installation position and insert the drain pipe into the sewer.
3) Check whether the user's three-hole socket is neutral, the fire danger is correct, and whether the ground wire is connected. If not, ground the motor on the ground wire reliably.
4) Add water to the bathtub until the highest nozzle is submerged, and check whether the function of the bathtub is complete, whether there is water leakage or whether the drainage is smooth. After confirming, proceed to the next step.
5) Hit the glass seal against the wall.
4. Shower/steam room
1) Check whether the package numbers are the same and check the packing list to see if the accessories are complete.
2) Install it according to the installation instructions.
3) Insert the drain pipe into the sewer.
4) Check the user's three-hole outlet zero line, fire hazard is correct, the ground line is connected, if not, the ground on the motor / steam engine is reliably grounded.
5) Test water test, whether the functions are complete and normal, whether there is water leakage or whether the drainage is smooth.